<callout type=“info” icon=“true”>
Identical locations must be used for each sequence if possible. Always used the “Copy image location” tool when setting up subsequent sequences
</callout>
Localizer
3 plane SSFP
Repeat in ref if needed to move heart to isocenter, then repeat in ref and delete all but final loc
Axial SSFP
include the entire aortic arch to diaphragm
Axial HASTE
Free breathing, include the entire aortic arch to diaphragm
Pseudo-SA
Perpindicular to long axis Loc
4ch cine SSFP
3PT at pseudo-SA RV free wall, LV free wall, apex from loc
Avoid the aortic valve
2ch cine SSFP
3PT at pseudo-SA LV anterior wall, LV inferior wall, from previous CINE
3ch cine SSFP
3PT at pseudo-SA aortic valve, pseudo-SA opposite point to AoV, apex from previous CINE
SA cine SSFP Stack
Perpindicular to 4 chamber. Stack at 10 mm intervals to cover the entire left ventricle